Electrak® XD Linear Actuators
Electrak® XD Linear Actuators are strong enough to take on hydraulic applications while, at the same time, being smarter, smaller and more efficient than competitive technologies. In addition to handling loads up to 25,000N, the XD offers extensive protection against even the harshest conditions and ingress and features enhanced controllability and diagnostics via onboard controls.
Electrak XD Feature Highlights:
- Dynamic/static loads up to 25000/32000 N
- Strokes up to 1200 mm
- Speeds up to 75 mm/s
- Duty cycle up to 100% depending on loading condition
- Life up to 275000 cycles
- Internal load holding brake
- Optional shock load dampening
- Manual override in case of power failure
- Constant monitoring and diagnostics
- Onboard electronics
- IP69K (static), IP67 (static) and IP66 (dynamic)
- Low-level switching
- Bus systems (CANopen® or SAE J1939)
Specifications
B055 | B080 | B160 | B200 | B250 | |
---|---|---|---|---|---|
Input Voltages (VDC) |
24 Vdc tolerance: (18-32) 48 Vdc tolerance: (36-60) |
||||
Min/Max Stroke Length: mm | 1200 | 1200 | 1000 | 800 | 650 |
Max Dynamic Load: N (lbs) | 5500 (1236) | 8000 (1798) | 16000 (3596) | 20000 (4496) | 25000 (5620) |
Max Static Load: kN (lbs) | 11.000 (2472) | 16.000 (3596) | 32.000 (7193) | 32.000 (7193) | 32.000 (7193) |
Max Speed: mm/s (in/s) load independent |
24V 65 (2.56) 48V 75 (2.95) |
24V 50 (1.97) 48V 50 (1.97) |
24V 25 (0.98) 48V 25 (0.98) |
24V 16 (0.63) 48V 20 (0.79) |
24V 16 (0.63) 48V 16 (0.63) |
Current Draw @ no load / max load |
24VDC/30A, 48VDC/15A | ||||
Full load duty cycle @ 25 ºC (77 ºF) |
25% | ||||
Screw / Nut Type | Ball | ||||
Operating temperature: ºC (ºF) | -40 to 85
(-40 to 185) |
||||
Protection Class: static / dynamic |
IP66, IP67, IP69K / IP66 | ||||
Restraining Torque: Nm (lbs) | 0 | ||||
End Play (Max): mm(in) | 1.200 (0.047) | ||||
Salt Spray Resistance (hours) | 500 | ||||
Actuator Weight kg | 11.9 @ 100 mm 23.4 |
11.9 @ 100 mm 23.4 |
11.9 @ 100 mm 21.3 |
11.9 @ 100 mm 19.2 |
11.9 @ 100 mm 17.7 |